PRODUCTS

Standard Type LF-AN2 series

Engineering

Technical Support

Highly efficient continuous conveyer furnace with far infrared heater and hot air blow.

Heating method:far infrared-ray and air blow

Working temperature:40~230°C

Temperature accuracy:±3.0°C (at230°C)

Clean level: Class10000

Standard Type LF-AN2 series

Specification

Model LF-AN2-154, LF-AN2-307
Heating method Far infrared-ray and air blow
Performance Working temperature 40 - 230°C
Temperature distrbution accuracy ±3.0°C (at230°C)
Stabilizing time for inside furnace Approx. 20min
Clean level Class 10000
Construction Inner wall Stainless steel SUS304
Outer wall Firing finish on mild steel
Insulation material Glass wool
Far infrared heater Far infrared ceramic heater (PLC-322)
Hot air heater Fin sheath heater (SUS)
Air supply fan 0.2W Turbo fan
Conveyer Teflon mesh belt Glass fiber +Teflon coating
Conveyer motor 60W Induction motor with speed controller
Controller Temperature control PID control with microcomputer in the temperature controller
Temperature setting/display method Digital setting ▲▼ Red LED digital display
Conveyer speed control Speed control pack
Conveyer speed setting / display type Digital setting by key ▲▼ Red LED digital display
Other functions Automatic start up and shut off
Heater control circuit SSR zero cross
Safety device Temperature abnormality , Earth leakage breaker, Conveyer abnormality, Fan abnormality, Emergency stop (on the operation panel)
Option Input-output terminal, Communication adapter, Recorder (6points), Watt-hour meter, 100V plug socket, Inlet/Outlet emergency stop switch, Electrostatic absorption unit, Cooling unit, Flow interruption sensor, Area sensor, Disconnection alarm, Excess temperature meter, Door abnormality, Touch panel control, Stainless mesh belt

Dimension / Utilities

Model LF-AN2-154 LF-AN2-307
Standard Length×Width×Height Length×Width×Height
Furnace casing dimension (mm) 1500×850×1470 3000×1150×1470
Outer dimension (mm) 2500×850×1470 4000×1150×1470
Belt width (mm) 400 (Effective width 350mm) 700 (Effective width 650mm)
Pass line (mm) 1150±25 1150±25
Power source (200V) / Electric current (A) 3 phase / 100A 3 phase / 200A
Far infrared heater (kw) / division 14.4 / 6 zone 43.2 / 6 zone
Hot air heater (kw) 3.0 4.5
Weight (approx. kg) 1000 2000